As a leading window film transmission meter (window tint meter) manufacturer, Lshtec provides a variety of window film meters to measure transmission rate, rejection rate, SHGC, TSER for materials such as automotive film, thermal insulation film, architectural film, thermal insulation glass, etc. There are mainly portable solar film transmission meters 86160 series, 86162 series, 86163 series, desktop demonstration window tint meters 86101, 86182, 86183, split transmission meters 86110A, 86110H. Whether you want to measure UV or IR rejection (940nm, 1400nm) or visible light transmittance,  you can find a suitable window film meter here.


86110A Split Transmission Meter

1.It is used for the transmittance testing of glass, plated film, organic materials, solar film and other translucent materials such as insulating glass, filmed glass, PMMA materials etc.
2.VL Peak wavelength:380-760nm
3.UV Peak wavelength:365nm
4.IR Peak wavelength:940nm

Browse:47

86110H Split Transmission Meter

1.It is used for the transmittance testing of glass, plated film, organic materials, solar film and other translucent materials such as insulating glass, filmed glass, PMMA materials etc.
2.VL Peak wavelength:380-760nm
3.UV Peak wavelength:365nm
4.IR Peak wavelength:1400nm

Browse:48

86101 Solar Film Transmission Meter (2nd)

1. Infrared central wavelength at 940nm, suitable for testing absorbing film
2. Adopt parallel optical path design, which is suitable for testing thick materials
3. Large LCD display with backlight on
4. Test the UV rejection rate, infrared rejection rate and visible light transmittance

Browse:31

How to select a suitable Window Tint Meter?

I. Select tint tester according to tested material

Window tint meter Window Film Stick-film glass Side windshield Front windshield
86160, 86160A


86162, 86162A
86163, 86163A

86101


86182, 86183

86110A,86110H
  1. Window film measurement: 86160 and 86160A window tint meters

  2. Side windshield measurement : 86162, 86162A, 86163, 86163A window tint meters

  3. Front windshield: 86110A and 86110H window tint meters

  4. Desktop window tint meter: 86101, 86182, and 86183

II. Selecte window tint meter according to testing wavelength

Window tint tester

86160

86162

86163

86101

86110A

86160A

86162A

86163A

86110H

86182 86183

Visible light
transmittance

365nm UV
940nm IR

1400nm IR


SHGC





  1. 940nm window tint meter is recommended to measure absorbing window film (glass)

  2. 1400nm window tint meter is recommended to measure metallic film or ceramic window film (glass)

  3. 86182 window tint meter can be used to test absorbing film, metallic film and ceramic window film

  4. If you need to measure both the rejection rate and the transmittance (visible light transmission), you can choose window tint meter 86163 or 86163A.

III. FAQ about window tint meter

1. Which test result is more accurate between window tint meters with 940nm and 1400nm light source?

  • No matter which window tint meter is used, the test data is objective and accurate.The wavelengths of 940nm and 1400nm are relatively representative wavelengths of sun spectrum.

  • Most of the absorbing films (heat-absorbing films) have better infrared blocking effect at 940nm, while the magnetron sputtering reflection film has better blocking effect at 1400nm such as metallic film and ceramic nano window film.

  • Please choose the right window tint meter based on your own window film category.

2. The differences between a metalic film and a heat-absorbing film?

  • The metalic film is produced by a magnetron sputtering process. A large amount of metal elements are added for a good reflection ability to the infrared film. It is insulated by the principle of reflecting infrared rays.

  • The heat-absorbing film is added with an infrared absorber during production and the infrared is absorbed by the film. It is insulated by the absorption principle and secondary heat radiation will be generated after the heat absorption is saturated.