86110A Split Transmission Meter
Measure front windshield, window tint, window film
Visible Light: 380-760nm
UV Peak wavelength: 365nm
IR Peak wavelength: 940nm
86110A split automotive window tint meter is an instrument that can simultaneously test the transmittance, infrared rejection rate and ultraviolet rejection rate. The tint meter is suitable for testing materials such as automotive solar film, automotive glass and architectural glass. The instrument is composed of two parts: the main part (PARTⅠ) and the auxiliary part (PARTⅡ). It adopts a split structure, which is especially suitable for testing installed glass or large-sized materials.
Technical Parameters
Parameter | Value |
---|---|
UV peak wavelength | 365nm |
IR peak wavelength | 940nm |
Visible light | 380-760nm, conform to CIE photopic luminosity function |
Resolution | 0%---10%: 0.1%; 10%---100%: 1% |
Measurement accuracy | ± 2% (colorless and uniform transparent materials) |
Test sample size | >40mm * 40mm |
Weight | 630 g |
Dimension | 130mm * 70mm * 84mm |
Power supply | Built-in lithium rechargeable battery |
Features
Split design convenient for testing glass already installed
The tint meter adopts a split design, with super strong magnetic force between the main machine and the auxiliary machine. It is convenient for on-site testing of the optical transmission of automobile front glass, building glass and large-sized materials
Three parameters can be measured at the same time
The 86110A split tint meter can test the transmittance, ultraviolet and infrared rejection rate at the same time
Data lock
With data lock function, the data remain on the interface after taking away the materials
Rechargeable lithium battery for simple and easy use
Built-in rechargeable lithium battery, there is no need to replace the battery, you can use one to two USB charging cable to charge the main and auxiliary machines at the same time
Parallel light path design
The automotive window tint meter uses a parallel light path design, which can test large thickness glass and ensure the accuracy of test data
Laser alignment to ensure accurate testing
The laser alignment function can ensure the precise alignment of the main and auxiliary machines during the measurement process. The accuracy of the instrument can be ensured
Packaging Details
No. | Description | Quantity | Unit |
---|---|---|---|
1 | 86110A Split Transmission Meter | 1 | pcs |
2 | Charger | 1 | pcs |
3 | User Manual | 1 | pcs |
4 | Certificate / warranty card | 1 | pcs |
5 | Packing box dimension 25*21*7 cm(L*W*H) | 1 | pcs |
FAQ
-
1. The difference between 86110A (940nm) and 86110H (1400nm) split transmission meters
The main difference between 86110A and 86110H is that the peak wavelength of the built-in infrared light source, 86110A: 940nm, 86110H: 1400nm, these two wavelengths are more representative, most of the absorption film has a better rejection effect on 940nm infrared. The metallic film (insulation by reflecting heat) has a better rejection effect on 1400nm infrared. Please choose the appropriate model according to your own film.
-
2. What is the maximum glass thickness that 86110A/86110H can measure?
The instrument use a parallel light path and the thickness of the test sample can reach more than 20mm. However, When measuring glass with a thickness greater than 20mm, the main body and auxiliary machine are not magnetic enough to be automatically adsorbed on both sides of the glass. The user need to hold the instrument for testing.