86162A Transmission Meter
Measure side windshied, window tint and window film
Measure visible light transmittance of 380nm-760nm
Measure UV rejection rate at 365nm and IR rejection rate at 1400nm
86162A is our portable and classic solar film tester. The sophisticated meter measures not only visible light transmittance but also UV rejection rate and IR rejection rate. When placing glass or film on the test slot, the screen will show the measurement data at once. It is mainly suitable for optical properties of various uniform and transparent materials such as solar film, laminated glass and automobile side glass.
Parameter
Parameter | Value |
---|---|
UV peak wavelength | 365nm |
IR peak wavelength | 1400nm |
Visible light | 380nm-760nm full wavelength, in line with CIE photopic luminosity function |
Resolution | 0.1% |
Measurement accuracy | better than ± 2% (colorless and uniform transparent material) |
Maximum sample thickness | <8mm |
Weight | about 165g(batteries excluded) |
Display | Segment LCD |
Dimension | 120mm × 25mm× 75mm (L*W*H) |
Power supply | 4 AAA alkaline dry batteries |
Feature
Convenient to use, Fast measurement
86162A window film transmission meter has simple operation and the measurement is fast. Just put the measured object into the test slot, then the visible light transmittance, ultraviolet and infrared rejection rate will be immediately displayed on the screen
Lightweight and handy
The instrument has a small size proper to outdoor measurement. The test slot is 8mm wide, which can directly test the car windshield
Lock data for relaxing reading
Due to the testing location or material properties, users may encounter that the instrument is placed at an angle difficult to read. 86162A developed the function of locking data to solve this problem by pressing HOLD button. Even if the meter moves, the data remains unchanged
Real-time dynamic calibration aids data stability during testing
86162A portable solar film transmission meter has real-time dynamic calibration function. When there is no test object in test slot, the meter will automatically return to the original data state to ensure more accurate test data
Low power consumption
Save energy
Powered by 4 AAA alkaline dry batteries, ultra-low power consumption and easy replacement. The meter will automatic shutdown after 3 minutes if there is no any operation making it more power-saving and energy-saving
Packing
No. | Description | Quantity | Unit |
---|---|---|---|
1 | 86162A Transmission Meter | 1 | pcs |
2 | AAA battery | 4 | pcs |
3 | User Manual | 1 | pcs |
4 | Certificate / warranty card | 1 | pcs |
5 | Packing box dimension 18*11*5 cm(L*W*H) | 1 | pcs |
FAQ
-
1. The difference between 86162 (940nm) and 86162A (1400nm) window film transmission meters
The main difference between 86162 and 86162A is that the IR bands are different. The infrared peak wavelength of 86162 is 940nm and the 86162A is 1400nm. These two bands are more representative bands. The absorbing film has a better infrared rejection effect at 940nm.The metallic film (Insulation by reflection) has a better infrared rejection effect at 1400nm. Please choose the appropriate instrument according to your own film.
-
2. The difference between 86162A and 86163A window film transmission meters
86162A measuring notch width is 8mm, 86163A measuring notch width is 6mm;
86162A use point light source, while 86163A use parallel light path. The latter has higher data accuracy for measuring thick materials.