86160 Transmission Meter
Special for window tint and window film (<0.8mm)
Measure IR/UV rejection rate, VLT
Enable to measure IR rejection rate, UV rejection rate and Visible Light Transmittance
Small size and easy to carry
86160 transmission meter is mainly used for testing the transmittance, ultraviolet and infrared rejectiong rates of automotive films. The biggest advantage of the instrument is its compact size and affordable price. It is the best choice for automotive solar film display exhibition, production, quality inspection and inspection. The pocket solar film transmission meter has been widely used in solar film manufacturers, automotive film distribution, automotive film retail sales system.
Parameter
Parameter | 86160 Transmission Meter |
---|---|
Size | 93mm *52mm *25m (L*W*H) |
Weight | 70g (exclude batteries) |
Maximum sample thickness | <0.8mm |
Resolution | 0.1% |
Accuracy | ±2%(Colorless and transparent material) |
Visible light Peak wavelength | 530nm |
UV Peak wavelength | 365nm |
IR Peak wavelength | 940nm |
Display | 128*128 Dot matrix LCD |
Battery | 4*AAA alkaline battery |
Feature
Compact and Convenient
Super small size which is very convenient to carry out
Easy to operate and display instantly
The light transmittance, UV rejection rate, IR rejection rate can be displayed immediately after putting the materials into the test slot
Real-time dynamic calibration function
The solar film transmission meter has real-time dynamic calibration function. It will self-calibrate if no material in the test slot which is to ensure the accurate test data
Lock data by pressing HOLD button
Press HOLD button can lock data on the screen. Taking away the material, the data is still showed on the screen
Low power consumption
Save energy
Powered by 4 AAA alkaline dry batteries, ultra-low power consumption and easy replacement. The meter will automatic shutdown after 3 minutes if there is no any operation making it more power-saving and energy-saving
Packing
No. | Description | Quantity | Unit |
---|---|---|---|
1 | 86160 Transmission Meter | 1 | pcs |
2 | AAA battery | 4 | pcs |
3 | User Manual | 1 | pcs |
4 | Certificate / warranty card | 1 | pcs |
5 | Cloth packing bag | 1 | pcs |
6 | Screwdriver | 1 | pcs |
7 | Spare screw | 1 | pcs |
8 | Packing box dimension 15*8*5 cm(L*W*H) | 1 | pc |
FAQ
-
1.The difference between 86160 (940nm) and 86160A (1400nm) window film transmission meters
The main difference between 86160 and 86160A is that the peak wavelength of the built-in infrared light source is different, 86160: 940nm, 86160A: 1400nm, these two wavelengths are more representative, most of the absorption film has a better blocking effect on 940nm infrared. The metallic film (insulation by reflecting heat) has a better blocking effect on 1400nm infrared. Please choose the appropriate model according to your own film category.
-
2. The difference between 86160 and 86162 window film transmission meters
The appearance and size is different and the measurement parameters are basically the same; the test notch of 86160 is 0.8mm, which is only suitable for testing materials with a thickness of less than 0.8mm;
The test notch of 86162 is 8mm, which can test films and stick-film glass. It can also directly measure the data of automobile side windshield.